Manuals

bosch fpd-7024 manual

Summary

Get your hands on the Bosch FPD-7024 manual! Download it now and master your device with ease. Find all the information you need.

This manual provides comprehensive information on the Bosch FPD-7024 fire alarm control panel, covering its features, applications, installation, operation, programming, troubleshooting, maintenance, and technical specifications. It also includes downloadable resources like the user manual, installation and operation guide, Program Record Sheet (PRS), and FCC Compliance Notice.

Overview

The Bosch FPD-7024 is a fire alarm control panel designed for reliable protection in a wide range of applications, including commercial, retail, and public buildings. It is UL-listed for central station, local, auxiliary, and remote station systems, offering flexibility in system configuration. The FPD-7024 supports four onboard initiating zones, which can be expanded to eight using the FPC7034 Fourpoint expander. This allows for the integration of both conventional and addressable fire detection devices, providing a comprehensive fire safety solution. The FPD-7024 is equipped with an alphanumeric LCD keypad for easy navigation and control of panel functions. The keypad displays system status information, provides prompts for programming, and indicates any alarms or trouble conditions.

Key Features

The Bosch FPD-7024 boasts a number of key features that contribute to its effectiveness and ease of use. These include⁚

  • Onboard Conventional Points⁚ The control panel offers four onboard initiating zones, allowing for the connection of conventional fire detection devices.
  • Off-board Addressable Points⁚ The FPD-7024 can support off-board addressable points, enabling integration with more advanced fire detection systems.
  • Remote LCD Keypads and LED Displays⁚ The control panel supports remote LCD keypads and LED displays, providing convenient monitoring and control from multiple locations.
  • Built-in Alphanumeric LCD Keypad⁚ The FPD-7024 features an integrated alphanumeric LCD keypad that provides clear information on panel functions and system status.
  • Support for Multiple System Configurations⁚ The FPD-7024 is versatile, supporting central station, local, auxiliary, and remote station systems to meet various application requirements.
  • UL Listing⁚ The FPD-7024 is UL-listed, ensuring compliance with stringent safety standards and providing peace of mind.

Applications

The Bosch FPD-7024 Fire Alarm Control Panel finds widespread application in a variety of settings due to its versatility and reliability. It is particularly suitable for⁚

  • Commercial Buildings⁚ Offices, retail stores, and other commercial establishments benefit from the FPD-7024’s comprehensive fire protection capabilities.
  • Retail Facilities⁚ The control panel’s ability to integrate with various fire detection systems makes it ideal for safeguarding large retail spaces.
  • Public Buildings⁚ Schools, universities, hospitals, and other public facilities rely on the FPD-7024 to ensure the safety of occupants.
  • Manufacturing Plants⁚ The control panel’s robust design and advanced features make it suitable for industrial settings with potentially hazardous conditions;
  • Healthcare Facilities⁚ The FPD-7024’s reliability and compliance with safety standards are essential for safeguarding patients and staff in hospitals and clinics.

Installation

The Bosch FPD-7024 Fire Alarm Control Panel requires careful and professional installation to ensure optimal performance and safety. The installation process typically involves several key steps⁚

  1. Site Preparation⁚ Ensure a suitable location for the control panel, taking into account factors like accessibility, power supply, and environmental conditions.
  2. Enclosure Installation⁚ Mount the enclosure securely to the wall or ceiling, following the manufacturer’s instructions and local building codes.
  3. Power Supply Connections⁚ Connect the control panel to the main power supply, ensuring proper grounding and compliance with electrical safety regulations.
  4. Terminal Connections⁚ Connect the various fire detection devices, notification appliances, and other system components to the control panel’s terminals, adhering to the wiring diagrams provided in the manual.
  5. System Testing and Commissioning⁚ After installation, thoroughly test the entire system to verify proper operation and functionality. Commissioning involves configuring the control panel and its components to meet the specific requirements of the installation site.

Power Supply Connections

The Bosch FPD-7024 Fire Alarm Control Panel requires a reliable power supply for uninterrupted operation. The power supply connections are crucial for the panel’s functionality and should be made with utmost care⁚

  1. Transformer Connection⁚ The control panel utilizes a transformer to step down the incoming AC power to a safe DC voltage. Connect the primary side of the transformer (black and white wires) to the unswitched 120V, 60Hz power source. Securely connect the secondary side (yellow and white wires) to the transformer terminals on the control panel.
  2. Battery Connection⁚ Connect the battery to the battery terminals on the control panel. Ensure proper polarity is maintained to avoid damage to the panel. The battery provides backup power in case of AC power failure.
  3. Grounding⁚ Ground the control panel enclosure and all associated wiring to prevent electrical shock hazards. Ensure proper grounding connections are made according to local electrical codes.
  4. Power On⁚ After completing the connections, switch on the AC power supply to the control panel. The control panel will undergo a self-test and initiate its normal operation.

Terminal Connections

The Bosch FPD-7024 Fire Alarm Control Panel features a series of terminals for connecting various components, including initiating devices, notification appliances, and other system peripherals. Proper terminal connections are essential for ensuring reliable system performance and safety.

  1. Initiating Device Terminals⁚ These terminals are used to connect smoke detectors, heat detectors, manual pull stations, and other initiating devices to the control panel. Each initiating zone has dedicated terminals for connecting devices. Ensure proper wiring and polarity are maintained for each device.
  2. Notification Appliance Terminals⁚ These terminals are used to connect notification appliances, such as bells, horns, strobes, and speakers, to the control panel. Each notification appliance circuit has dedicated terminals. Proper wiring and polarity are crucial for ensuring audible and visual alarms are triggered effectively.
  3. Relay Terminals⁚ The control panel features relay terminals that can be used to activate external devices or systems, such as remote annunciators, automatic fire suppression systems, or building management systems. These terminals allow for integration with other building systems for enhanced safety and control.
  4. Communication Terminals⁚ The control panel may have dedicated terminals for connecting to communication devices, such as a central station, remote annunciators, or a network. These connections enable remote monitoring and reporting of system events.

Operation

The Bosch FPD-7024 Fire Alarm Control Panel is designed for reliable and efficient operation, providing comprehensive fire alarm and notification capabilities. The control panel utilizes a user-friendly interface, including an alphanumeric LCD keypad, LED indicators, and a built-in sounder.

The keypad provides access to various system functions, such as programming, monitoring, and troubleshooting. LED indicators, such as Power, Alarm, Trouble, and Supervisory, visually indicate the system’s status and any ongoing events. The built-in sounder provides audible alarms and notifications, alerting occupants to fire hazards or system malfunctions.

The FPD-7024 offers different operational modes, including Normal Operation, Alarm Operation, Trouble Operation, Supervisory Operation, and Programming Mode. These modes are designed to provide clear and informative feedback on the system’s status and any ongoing events.

Understanding the Built-in Keypad

The Bosch FPD-7024 features an alphanumeric LCD keypad, providing a user-friendly interface for managing and monitoring the fire alarm system. The keypad has a two-line by 16-character display that shows various system information, including current status, events, and menu options. The top line typically displays general system status, while the second line provides specific details related to the current system condition.

When keys are pressed, the keypad displays the current action on the top line and shows rotating menu choices on the second line. A built-in sounder provides audible feedback for keystroke entries and acts as an interior warning device. The keypad also features LED indicators, including Power, Alarm, Trouble, and Supervisory, to visually signal system status and events.

Normal Operation

During normal operation, the Bosch FPD-7024 displays a green Power LED, indicating that the system is receiving power. If the system is programmed to require a PIN, the keypad prompts for the PIN upon opening. If a PIN is not required, the control panel displays the date and time. The system remains in this state until a triggering event occurs.

The FPD-7024 continuously monitors the fire alarm system for any potential hazards, including smoke, heat, or other triggering conditions. If a detector senses an alarm condition, the system immediately initiates the appropriate response based on its programming, such as sounding alarms, notifying designated personnel, or activating other safety measures.

Alarm Operation

When an alarm condition occurs, the FPD-7024’s display shows “ALARM” on the top line. The second line of the display identifies the specific point or zone that triggered the alarm. The system’s built-in sounder activates with a steady tone, and any notification appliances programmed for the current alarm condition will also activate.

The alarm condition remains active until it is manually reset using the keypad. The Reset key briefly interrupts power to the detectors, allowing them to reset and clear any off-normal conditions. The alarm condition can also be silenced by pressing the Silence key, which quiets the bells/sirens but does not address the underlying cause of the alarm. The system will continue to monitor the alarm condition until it is resolved.

Trouble Operation

When the FPD-7024 detects a trouble condition, such as a wiring fault, a power failure, or a malfunctioning component, the system’s sounder activates briefly every 10 seconds. The Trouble LED on the keypad illuminates, indicating the presence of a problem. The display will show “TROUBLE” on the top line, and the second line will provide details about the specific trouble condition.

This intermittent sounder activation serves as a visual and audible alert, prompting the user to investigate the issue. The user should refer to the troubleshooting guide and the relevant sections of the manual for instructions on resolving the trouble condition. The system will continue to monitor and display the trouble condition until it is rectified.

Supervisory Operation

The FPD-7024 features a supervisory mode to alert users to potential issues that may not trigger an alarm but could indicate a problem in the system’s functionality. When a supervisory condition occurs, the system’s sounder will activate briefly every 10 seconds, prompting the user to investigate. The Supervisory LED on the keypad will illuminate, signaling that a supervisory event has occurred.

The display will show “SUPERVISORY” on the top line, while the second line will provide information about the specific supervisory event. This could include a low battery condition, a communication failure, or an open circuit in a detector loop. The supervisory mode helps ensure the fire alarm system is functioning optimally and proactively notifies users of potential issues before they escalate.

Using PIN Numbers

The Bosch FPD-7024 fire alarm control panel offers the option to implement PIN number security for enhanced access control. This feature adds an extra layer of protection, limiting access to specific functions and ensuring authorized personnel are the only ones able to make critical changes.

For systems configured without PIN numbers, commands like Reset and Silence can be executed directly by pressing the corresponding keys once the panel is opened. However, for systems requiring a PIN, users must first enter their assigned four-digit PIN number before accessing these commands. This provides a secure method to prevent unauthorized manipulation of the system settings.

Programming

The Bosch FPD-7024 fire alarm control panel offers a comprehensive programming interface that allows technicians to configure various settings and customize the system’s behavior. These settings include defining initiating zones, configuring detectors, setting alarm parameters, and customizing notification appliances.

Programming the FPD-7024 is typically done through the built-in LCD keypad, providing a user-friendly way to access and modify various system parameters. The manual provides detailed instructions and explanations for each programming step, ensuring that technicians can navigate the menus effectively and make the necessary adjustments to meet specific site requirements.

Troubleshooting

The Bosch FPD-7024 manual provides a comprehensive troubleshooting guide designed to assist technicians in identifying and resolving issues that may arise with the fire alarm system. This section covers a wide range of potential problems, from common wiring faults and detector malfunctions to communication errors and system configuration issues.

The troubleshooting guide is structured logically, starting with basic checks and progressing to more complex diagnostics. It includes detailed descriptions of error codes, their potential causes, and recommended corrective actions. The manual also provides helpful diagrams and illustrations to aid in visual identification of components and wiring connections.

Maintenance

The Bosch FPD-7024 manual emphasizes the importance of regular maintenance to ensure the fire alarm system remains in optimal operating condition. It details a comprehensive maintenance schedule, outlining recommended tasks and their frequency. These tasks may include cleaning and inspecting detectors, checking wiring connections, verifying battery performance, and conducting functional tests of the control panel and notification appliances.

The manual also provides guidance on specific maintenance procedures, such as replacing batteries, calibrating detectors, and updating firmware. Additionally, it stresses the importance of keeping accurate maintenance records, which can help track system performance and facilitate future troubleshooting.

Technical Specifications

The Bosch FPD-7024 manual provides a detailed breakdown of the control panel’s technical specifications, covering key aspects like power requirements, communication capabilities, and environmental limitations. This information is crucial for installers and technicians to ensure proper installation and operation within specific environments.

The manual outlines details such as the panel’s operating voltage range, battery backup time, communication protocols supported, and environmental operating temperature and humidity ranges. It also lists the dimensions of the control panel and its enclosure, aiding in space planning and installation requirements.

Downloads

The Bosch FPD-7024 manual offers a convenient section for users to access essential downloadable resources. These resources are designed to support both installation and operation of the control panel. This section typically includes links to PDF files, providing users with readily available information.
The downloadable resources may include the full user manual, a detailed installation and operation guide, a program record sheet (PRS) for documenting system configurations, and a FCC Compliance Notice for regulatory compliance. These documents are valuable tools for understanding the system’s functionality, proper installation procedures, and regulatory requirements.

Leave a Reply